| Your are there : Home > Our Services |
|
| |
|
|
Engineering centre - Research and development
- Printed circuit board conception. CI routing
- Back-lit front panel conception
- Conception of electronic equipment following technical specifications
- Mechanical conception (CAO 3D, Solidworks 2009)
|
|
|
| |
Machining - NC table: Mecamatic MG100, Mecanumeric Mecaplus 2110 table 1000x2000. Charly 2U table 400x600. Microtonic 2 heads
- Data transfer via Mastecom X10 for machining in 3D
- Engraving, NC machining on polycarbonate or PMMA
- Associated metrology - Three dimensional statement
|
|
|
|
|
| |
|
|
Blasting - Sand blast Finimac V1
- Frosted and improve the state on all the materials. Allows a better paint adhesion
- Diverse sand calibre
|
|
|
| |
Paint - AMC paint booth with integrated vacuum cleaner, 800x1500 table, MPC S79 oven
- Application technology control allowing reproducibility
- Paint composition management
- Checks mastery on finished product following the technical specifications
- Shine check by Gloss-meter Super Glos 60. Hold control with squaring comb
- Shade check by master customers and/or associated standard (FED std 595B...)
|
|
|
|
|
| |
|
|
Engraving laser - Laser STARMARK DM1. Crystal laser Nd: YAG Waelength: 1064 nm
- Average power: 40W. Table capacity xy: 500x500
- Optimal marking process assuring a repetitiveness compliance with customers requirement
|
|
|
| |
CMS Pick & wiring - Auto CMS wiring: AUTOTRONIK BS 387 V
- Soldering oven: TECHNOPRINT MISTRAL 460
|
|
|
|
|
| |
|
|
Burning-in - Thermal test chamber VOTSCH VT 40 30 with electronic drive temperature range -90°/+180°
- Ramp of 2°C/mn, bearing of 1 hour. Trial bulk: 335 l
- Trial program in temperature and relative humidity of civilian or military cycle following the associated standard (ex: DO160D) or customers specification
==> Allows component and welds test which deletes the beginning of life breakdowns and guaranties the whole reliability |
|
|
| |
Global harmonization - Colour cameras and monochrome CDD. High resolution sensor 1300/1300 pixels. High sensibility 0.00014 lux. Integration until 60 sec
- Conventional global harmonization in false colour of the back-lit front panel following the customers specification. Check by image
|
|
|
|
|
| |
|
|
Control and specific harmonization - Spectroradiometer DTS-320-201 (NVIS) in compliance with standard MIL-STD-3009 (0.1 foot Lambert)
- Luminance: +-4%, radiation: +-5%, chromatics: +-0.0015%. Control of luminance, radiation and chromatics NIVS
==> Allows the spectral optical analysis on a wavelength from 380 mm to 930 mm as well as the edition of a test report (ATP ATR) |
|
|
| |
Assembly and final control - Assembly following production range. Test lights flights in the darkroom
- The identification by P/N, S/N, MRF and DMF assure the traceability
|
|
|
|
|
| |
|
|
Conditioning and expeditions - Vacuum conditioning, retractabe sheath. ESD envelope
- Conformity certificate. Material certificate
- Daily purchase. Computer follow-up
- Specific conditioning following the technical specifications. specific identifications and product traceability
|
|
|
|
|