BURNING-IN

• Thermal test chamber VOTSCH VT 40 30 with electronic drive temperature range -90°/+180°

• Ramp of 2°C/mn, bearing of 1 hour. Trial bulk: 335 l

• Trial program in temperature and relative humidity of civilian or military cycle following the associated standard (ex: DO160D) or customers specification

==> Allows component and welds test which deletes the beginning of life breakdowns and guaranties the whole reliability